Artikelnummer: DD1218512
Verzending : Gratis verzending
Beschikbaarheid : Product is op voorraad
€447,99 Oorspronkelijke prijs was: €447,99.€214,71Huidige prijs is: €214,71.
watch mtg coaxial tester timing multifunction timegrapher machine
Specifications:
Measuring possibilities | Rate deviation, amplitude, beat error of mechanical watches and diagram recording of the beat noise. |
Frequency numbers | It can selected out the common beat number automaticly, also can selected out the less common beat number by manual. |
Rate deviation measurement | the range of deviation is ± 999 sec / day, precision 1.0 sec/day. |
Amplitude measurement | Numerical display in degrees, resolution is 1°,measuring range: 100°to 360° (the lift angle can affect the amplitude, range: 30°to 70°.Under normal circumstances, the amplitude value do not exceed 360°.) |
Measuring period times for the average numerical results | 2s, 4s, 8s, 10s, 20s, 30s, 30s, 60s. |
Measuring of the Beat error(Frequency error) | Numerical display in milliseconds. Resolution is 0.1 milliseconds; the measuring range is 0-9.9 ms. |
Lift Angle | the measuring range is 30 ° to 70 °, the factory set it to 52 °. |
Supply voltage | single-phase AC 100 Vï½240V ± 10% two-line. |
Measure positions | 1 to 6 positions. |
Use of the environment | 0 â to 50 â, relative humidity:0 to 80% RH |
Shell | Light grey plastic |
Features:
– It is a precise mechanical watches test instrument, it is used for multi-testing by
watch manufacturers and watch technician.
– The frequency diagram of the watch can be displayed in the LCD screen.
– According to different watches, the instrument will automatically adjust optimal
signal level during testing.
– The instrument will automatically calculate the rate, amplitude, beat error, and
display them by data in real time.
– For the conventional beat, the instrument can automatically response; for the
special beat, can manually select.
– The sampling period can selected by 2 seconds, 4 seconds, 6 seconds, 8 seconds,
10 seconds, 20 seconds, 30 seconds, 60 seconds, and the average of corresponding
period will be regard as the precise value of the watch.
– Six kinds of testing position can be adjusted, and the simulation sound can be play in
the speaker or mute
Automatic:
E following beat numbers are selected by automatic selection mode:
12000
(If the tested beat is not in automatically selection, the instrument will display the closest
beat number, but the test result is not correct. At this time, use the manual mode to select
the relative beat.)
Manual selection
It can selected out the beat number that Automatic select can not identify and rare beat number.
The following beat are selected by Manual selection mode:
3600
12600
14760
17897
21306
Lift Angle:
The lift angle is 52° for many common movements, therefore the lift angle value of instrument for factory
is set to 52°. This value is required to calculate the amplitude and must be selected according to the watch
movement. The lift angle can be set to between 30°and 70°
Period:
The measuring period selectable:2s
Use to recalculate the average values of the test result.
Package included:
1 x Watch Timing Machine Timegrapher
1 x Charger
1 x Manual
Features
Measuring possibilities | Rate deviation, amplitude, beat error of mechanical watches and diagram recording of the beat noise. |
Frequency numbers | It can selected out the common beat number automaticly, also can selected out the less common beat number by manual. |
Rate deviation measurement | the range of deviation is ± 999 sec / day, precision 1.0 sec/day. |
Amplitude measurement | Numerical display in degrees, resolution is 1°,measuring range: 100°to 360° (the lift angle can affect the amplitude, range: 30°to 70°.Under normal circumstances, the amplitude value do not exceed 360°.) |
Measuring period times for the average numerical results | 2s, 4s, 8s, 10s, 20s, 30s, 30s, 60s. |
Measuring of the Beat error(Frequency error) | Numerical display in milliseconds. Resolution is 0.1 milliseconds; the measuring range is 0-9.9 ms. |
Lift Angle | the measuring range is 30 ° to 70 °, the factory set it to 52 |
Supply voltage | single-phase AC 100 Vï½240V ± 10% two-line. |
Measure positions | 1 to 6 positions. |
Use of the environment | 0 â to 50 â, relative humidity:0 to 80% RH |
Shell | Light grey plastic |
Geen lid? Account aanmaken
Heb je al een rekening? Meld je hier aan